KK High Temperature Constant-Wattage Heating Cable

Product Highlights

checkmark Temperatures up to 500oF (260oC)

checkmark Power remains constant regardless of temperature

checkmark Can be cut-to-length at job site

checkmark Ideal for a wide range of high temperature applications:

  • Viscosity control
  • Asphalt lines
  • Heavy oil lines
  • Nuclear environments
  • Locations where halogens are not permitted
  • Process lines subject to high pressure steam blow down

Specifications

  • Maximum exposure temperature is 500oF (260oC)
  • Moisture, chemical, flame, and radiation resistant
  • 12AWG bus wires
  • Dimensions 0.2" x 0.3" (5 x 8mm)
  • 30 lb. (14kg) per 500-foot (152m) spool
Approvals

FM

Ordinary Locations
Hazardous Locations:
Class I Division 2 Groups B, C, D
Class II Division 2 Groups F, G
Class III Division 2

RoHSREACH

Approval valid only when used with appropriate heating cable and installation accessories, and installed in accordance with all applicable instructions, codes, and regulations.

Maximum Circuit Length in ft (m)

Cable 120VAC 208VAC 240VAC 277VAC 480VAC
4 watts / ft 12AWG
(13 watts / m)
310
(94)
537
(164)
620
(189)
716
(218)
1240
(378)
8 watts / ft 12AWG
(26 watts / m)
220
(67)
381
(116)
440
(134)
508
(155)
880
(268)
12 watts / ft 12AWG
(39 watts / m)
180
(55)
312
(95)
360
(110)
416
(127)
720
(220)
18 watts / ft 12AWG
(59 watts / m)
120
(37)
208
(63)
240
(73)
277
(84)
480
(146)

Circuit Module Length in ft (m)

Cable 120VAC 208VAC 240VAC 277VAC 480VAC
4 watts / ft 12AWG
(13 watts / m):
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
8.0
(2.4)
8 watts / ft 12AWG
(26 watts / m):
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
6.0
(1.8)
12 watts / ft 12AWG
(39 watts / m):
2.0
(0.6)
4.0
(1.2)
4.0
(1.2)
4.0
(1.2)
7.0
(2.1)
18 watts / ft 12AWG
(59 watts / m):
1.75
(0.5)
3.0
(0.9)
3.5
(1.1)
4.0
(1.2)
5.5
(1.7)

Note: when ordering, please allow a minimum of 1 module length extra for terminations.

 

KK High Temperature Constant-Wattage Heating Cable Specification Sheet

Ordering Information

Part Number Matrix

Connection / Termination Kits
Part Number Kit Enough to Complete
KCABUC Universal Connection / Termination Kit Two end terminations and one input connection, or one power input splice. Note: Requires a double hub junction box and pipe straps.
KCABKC Lead / End Seal Kit Five lead and end terminations.
KCABSK Splice Kit One in line splice or one tee splice. Note: Requires pipe standoff, pipe straps, and single hub junction box.
KCABLP Lead Termination Kit One lead termination. Note: Requires RTV sealant.
KCABEP End Termination Kit One end termination. Note: Requires RTV sealant.

 

KK Connection /Termination Kit Specification Sheet

Temperature Controller

A temperature controller is required for this product. Check out temperature controller section for a complete selection of temperature controllers.

Accesories

Adhesive Tape

Helps to isolate the cable from the insulation and provides intimate contact with surface to be heated.

Part Number Description
PSAT36 Pressure Sensitive Fiberglass Adhesive Tape
0.5" x 108' (13mm x 38m)
Temperature limit: 350oF (176oC)
 
AAT260
AAT2180
Aluminum Adhesive Tape
2" x 180' (51mm x 55m) / Temperature limit: 350oF (176oC)
2" x 180' (51mm x 55m) / Temperature limit: 550oF (288oC)

 

Caution Label

Required by code for every 100ft (3m) of pipe.

Part Number Description
BCLCAB Electrical heat trace warning label. Required by code for every 10ft (3m) of pipe.

 

Heat Conductive Putty

Used to fill voids between cable and pipe surface.

Part Number Description
 
HCP1
HCP3
Heat Conductive Putty. Used to fill voids between cable and pipe surface.
1 lb. (0.5kg)
3 lb. (1.4kg)

 

Monitor Light Kit

Provides a continuity check at the termination end of a cable circuit.

Part Number Description
MLK1001 Single hub; 120VAC
MLK2001 Single hub; 240VAC
MLK1002 Double hub; 120VAC
MLK2002 Double hub; 240VAC
MLBCAB001 120VAC replacement bulb
40180 240VAC replacement bulb

 

Pipe Reducer

Part Number Description
BPRCAB010 Adapts 0.75" NPT male to 1" NPT female

 

Pipe Standoff

Cast aluminum fitting.

Part Number Description
PSOCAB010 1.00" thread
PSOCAB075 0.75" thread

 

Pipe Strap

Stainless steel pipe straps used to secure pipe standoff to pipe.

Part Number Description
BPSCAB2-6 Stainless steel pipe straps used to secure pipe standoff to pipe.
Adjustable from 2" to 6" (51 x 152mm)

 

RTV Sealant

Silicone sealant used to seal lead pouches, end pouches, and pipe standoffs.

Part Number Description
RTV3.0 Silicon sealant used to seal lead pouches, end pouches, and pipe standoffs. 3 oz. (89ml)

 

Support

Documents
Click here to view larger image


Show Picture 1Show Picture 2Show Picture 3

Click here to view larger image


 E-mail this product to a friend



 


SLMCAB Mid-Temperature Self-Regulating Heating Cable

CTL Cut-to-Length Silicone Rubber Heating Tapes

FE General Purpose Constant-Wattage Heating Cable

KE Harsh Environment Constant-Wattage Heating Cable

SLCAB Self-Regulating Heating Cable