Heat geometries that are
unavailable with standard cloth jacket product
offering
Application-specific wattages
Wide range of materials
and options available to match your application
Temperatures up to 1100°F
(593°C)
Utilize industry-leading
engineering services
Ordering Information
Contact your local BriskHeat representative or BriskHeat direct for more information.
Configure-to-Order Cloth Jacket Options
Jacket Construction
Power Configuration
Temperature Control
- Centipede® Temperature Control System
- Built-in Controlling Thermostat
- Field Replaceable Controlling Thermostat
- Other External Temperature Control Options
- Built-in Temperature Sensors
Safety Features
Accessories
Click Here for a Cloth Jacket Specification Sheet
Jacket Construction
Liner and Facing Material
Liner is the layer between the object to be heated and insulation.
Facing is the outer shell of the jacket.
|
TEFLON® Grey - Standard facing material. Exposure temperatures up to 500°F (260°C). Up to Class 10 environments. |
|
|
Chemstat - For cleanroom class 10. Exposure temperatures up to 600°F (315°C). |
|
|
High Temperature (Samox®) - High temperature cloth. Exposure temperatures up to 1100°F (593°C). Up to Class 100 environments. |
|
|
Grey Silicone Cloth Adds a degree of moisture and chemical resistance. Exposure temperatures up to 482°F (250°C). |
|
|
Aluminum - Facing material option. Exposure temperatures up to 482°F (250°C). |
|
|
Fiberglass cloth - Liner material option. Exposure temperatures up to 900°F (482°C). Up to Class 100 environments. |
|
TEFLON® is a registered Trademark of DuPont used under license.
Insulation Thickness
Thickness is determined based on your application.
Type of Closure
|
|
|
Power Configuration
Voltage
- Any voltage up to 600VAC
Phase
- Single
- 3 Phase (Wye)
- 3 Phase (Delta)
Frequency
- 60Hz
- 50Hz
- DC
Power Plug / Connector for Lead and Jumpers
![]() Click to Enlarge |
![]() Click to Enlarge |
![]() Click to Enlarge |
![]() Click to Enlarge |
|
|
Temperature Control
Centipede® Temperature Control System
- Controls each heating jacket
- Compact autotuned-PID temperature controller
- Platinum RTD
- Dual LED light
- Networked together with CAT5 communication cable
- Control and monitor the entire system from an easy to use operator interface
- More details
Built-in Controlling Thermostat
Thermostats can be installed to act as the primary temperature control device. The use of controlling thermostats eliminates the need for external temperature control. It should be noted that controlling thermostats have a limited life span and precision. (Not available above 277VAC)
- 180°F (82°C), 30°F (17°C) differential
- 248°F (120°C), 50°F (28°C) differential
- 302°F (150°C), 50°F (28°C) differential
- 347°F (175°C), 50°F (28°C) differential
- Other
Field Replaceable Controlling Thermostat (Patent 6,710,312)
Heating jacket can be configured to allow easy access to built-in controlling thermostat.
Other External Temperature Control
BriskHeat® offers many different types of temperature control options. Click Here for more details.
Temperature Sensor
Sensor can be built-in heating jacket or be applied separately.
- Platinum RTD with Centipede® Control Option
- Type J Thermocouple
- Type K Thermocouple
- Thermistor
- Other- please specify
Safety Features
Built-in High-Limit Thermostat
Used to prevent over-temperature conditions in the event of main controller failure. If required, select a thermostat that is 20% higher than the required operating temperature, yet low enough to avoid damage to the system in the event of controller failure. (Not available above 400VAC)
- 248°F (120°C), 50°F (28°C) differential
- 302°F (150°C), 50°F (28°C) differential
- 347°F (175°C), 50°F (28°C) differential
- 392°F (200°C), 50°F (28°C) differential
- 482°F (250°C), 50°F (28°C) differential
- Other
Built-in Low-Limit Thermostat
Used to indicate a low temperature condition. If required, thermostats can be installed to provide a dry contact to be used as an alarm signal via a separate cord (not available above 277VAC).
- 180°F (82°C), 30°F (17°C) differential
- 248°F (120°C), 50°F (28°C) differential
- Other
Grounded Heating Element
Patented grounded heating element for temperature usage up to 482°F (250°C).
Approvals
-
73/23/EEC -

Accessories